Trade terms: EXW/ FCA/ FOB/ CIF/ CIP/ DDU(In some areas)
Delivery time:
1. Complete in stock:Can be shipped within 24 hours
2. in stock(engine and alternator): 1~3days for open type/ 2~5days for silent type
2. out of stock: need to be confirmed
Emergency production can be arranged, if need please consult the staff for details
Wanding CCEC Cummins series, the engine is produced by Chongqing Cummins Engine Co., Ltd., a joint venture of American
Cummins in China, product power range covers 275KVA~2000KVA. Click inquiry for more information.
In 1995, with a 50:50 shareholding ratio, with diesel engine manufacturing as its main business, CCEC Engine Company was established in the Martyrs Cemetery
of Shapingba District, Chongqing City. It is a professional manufacturer of heavy-duty and high-power engines, with total assets of more than 2 billion yuan and More than 1400 employees.
CCEC mainly produces M11, NT/QSN, K19/QSK19, K38/QSK38, K50/QSK50 series electromechanical control diesel engines. It is a leading engine manufacturing base in China
-Power from the century-old company American Cummins design
-Support global warranty, worry-free after-sales service
☆The cylinder block and cylinder head adopt integrated design, low failure rate, excellent lubrication system, low parasitic power, durable and excellent reputation.
☆Overall modular design, integrated in blocks, easy maintenance
☆Parts can be disassembled, high reusability; compact structure Six cylinders and one cover overall design, more compact structure, easy to arrange and maintenance
☆Cummins advanced PT fuel system with unique over-speed protection, low-pressure fuel supply, few pipelines and low failure rate
☆Advanced Cummins exhaust gas turbocharger to ensure sufficient engine air intake, full combustion and high efficiency.
☆Pressure type impulse exhaust pipe, making full use of waste energy and improving engine low load efficiency
Different type
Alternators of brands such as Leroy somer, Marathon, and Stamford are optional, and Chinese-made alternators such as WANDING
are also optional. Voltage optional 220V/380V/400V/10500V, single phase or three phase.
Control System brands available from SmartGen, Fortrust, DeepSea and others
About us
▼Sales Promise: Wanding Genset offers a full line of new, high quality products. Each unit undergoes rigorous factory testing.
▼Warranty: Under our standard terms: one year from the time you receive the goods, or 1000 hours of running (whichever comes first).
Service and parts are available from Wanding Genset or from your local dealer.
▼Technical Consulting Service: 7X24 hours online technical service consultation and highly customized service are supported.
Overseas project
☉For individual users: inquiries welcome! Don't know about diesel generator sets? No need to worry! Once purchased, free technical consultation for life.
☉For dealers: inquiries welcome! Get the best dealer exclusive price and service, we offer free brand customization.
Model | Genset | Diesel engine | Dimensions&Weight | ||||||||||
PRP* KW/KVA | ESP* KW/KVA | Fuel consumption g/kW·h | Engine model | Engine power KW/KVA | Cylinder | Bore*Stroke MM | Displacement L | Open type Dimensions MM | Weight KG | Silent type Dimensions MM | |||
WD-200 | 200/250 | 220/275 | ≤200 | QSNT-G6 | 243/265 | 6 | 140*152 | 14 | 3000*1206*1760 | 2590 | 4000*1600*2150 | ||
WD-220 | 220/275 | 242/302.5 | ≤200 | QSNT-G7 | 261/291 | 6 | 140*152 | 14 | 3000*1238*1760 | 2632 | 4000*1600*2150 | ||
WD-250 | 250/312.5 | 275/343 | ≤200 | QSNT-G1 | 291/325 | 6 | 140*152 | 14 | 3000*1238*1760 | 2800 | 4000*1600*2150 | ||
WD-280 | 280/350 | 308/385 | ≤200 | QSNT-G2 | 321/358 | 6 | 140*152 | 14 | 3100*1301*1815 | 2800 | 4000*1600*2150 | ||
WD-320 | 320/400 | 352/440 | ≤200 | QSNT-G3 | 358/392 | 6 | 140*152 | 14 | 3100*1301*1815 | 2912 | 4400*2000*2300 | ||
WD-360 | 360/450 | 396/495 | ≤200 | QSK19-G15 | 405/448 | 6 | 159*159 | 18.9 | 3200*1450*1980 | 3000 | 4400*2000*2300 | ||
WD-400 | 400/500 | 440/550 | ≤200 | QSK19-G13 | 451/501 | 6 | 159*159 | 18.9 | 3242*1333*2018 | 3200 | 4400*2000*2300 | ||
WD-460 | 460/575 | 506/632.5 | ≤200 | QSK19-G12 | 503/565 | 6 | 159*159 | 18.9 | 3388*1245*2018 | 3450 | 4900*2250*2600 | ||
WD-500 | 500/625 | 550/687.5 | ≤200 | QSK19-G18 | 564/624 | 6 | 159*159 | 18.9 | 3650*1550*2123 | 3600 | 4900*2250*2600 | ||
WD-520 | 520/650 | 572/715 | ≤206 | QSK19-G4 | 575/634 | 6 | 159*159 | 18.9 | 3700*1600*2180 | 3730 | 4900*2250*2600 | ||
WD-550 | 550/687.5 | 605/756 | ≤206 | QSK19-G11 | 606/667 | 6 | 159*159 | 18.9 | 3950*1550*2100 | 3800 | 4900*2250*2600 | ||
WD-600 | 600/750 | 660/825 | ≤206 | QSK19-G20 | 668/739 | 6 | 159*159 | 18.9 | 4300*1550*2100 | 4000 | 4900*2250*2600 | ||
WD-640 | 640/800 | 704/880 | ≤206 | QSK19-G21 | 724/801 | 6 | 159*159 | 18.9 | 4300*1550*2100 | 4200 | 6000*2300*3100 | ||
WD-728 | 728/910 | 800/1001 | ≤206 | QSK38-G9 | 826/911 | 12 | 159*159 | 37.8 | 4650*1850*2468 | 4500 | 6000*2300*3100 | ||
WD-800 | 800/1000 | 880/1100 | ≤206 | QSK38-G10 | 903/997 | 12 | 159*159 | 37.8 | 4870*2435*2259 | 5000 | 6000*2300*3100 | ||
WD-900 | 900/1125 | 990/1237.5 | ≤206 | QSK38-G11 | 1022/1129 | 12 | 159*159 | 37.7 | 4800*1850*2331 | 5400 | 8000*2600*3200 | ||
WD-1080 | 1080/1350 | 1188/1485 | ≤206 | QSK38-G19 | 1183/1333 | 12 | 159*159 | 37.7 | 5100*2435*2259 | 800 | 10000*3000*3300 | ||
WD-1100 | 1000/1250 | 1100/1375 | ≤206 | QSK38-G12 | 1134/1254 | 12 | 159*159 | 37.8 | 5236*2000*2397 | 6000 | 10000*3000*3300 | ||
WD-1200 | 1200/1500 | 1320/1650 | ≤206 | QSK38-G14 | 1346/1489 | 12 | 159*159 | 37.8 | 5300*2435*2259 | 7000 | 10000*3000*3300 | ||
WD-1280 | 1280/1600 | 1408/1760 | ≤206 | QSK38-G15 | 1399/1548 | 12 | 159*159 | 37.8 | 5300*2435*2259 | 7800 |
*Emergency Standby Power (ESP)
This generator rating is normally used for equipment that is connected to a commercial power utility but used to provide emergency power when that utility suffers an outage.
The rating represents the maximum amount of power a generator set can deliver. The average load factor is set by the manufacturer but is usually 70% of full capacity, and there is no overload capability.
ESP-rated generators may run for a maximum of 200 hours per year under Environmental Protection Agency emissions regulations.
This generator set rating is normally applied to generators used without a connection to a commercial power utility. Typical applications include temporary use, load management,
or to power off-grid locations such as wilderness outposts and remote mining, quarrying, or drilling operations. The average load factor is usually 70% of full capacity, but unlike an ESP-rated generator,
a PRP-rated engine can run for an unlimited number of hours. A 10% overload capacity is permissible for short periods of time (a maximum of one hour per 12 hours, and a cap of 400 hours per year).